Carbon canister desorption air drying device
When conducting adsorption and desorption tests on charcoal cans, there are certain requirements for the absolute humidity of the ambient air.
EPA § 86.1232-96 states:
The absolute humidity range of the air is 7.14g/kg ± 3.57g/kg
If the environmental humidity approaches the upper limit of 10.71g/kg. We need to use a drying device.
usage method:
Provide dry air to the testing cabinet through a designated entrance.
The ventilation time of dry air can be consistent with the opening time of the test cabinet or only supplied during the desorption time. When supplying dry air, avoid opening the cabinet door of the test cabinet
technical parameter
Carbon canister test gas supply pressure: 1Bar
A testing cabinet requires ≥ 30L/min
Power consumption: 1200W, 220V,50Hz
Maximum gas supply: 1M3/min
Operating environment temperature: ≤ 45℃
Compressed air supply: ≥ 6Bar
Total weight of equipment: 100KG